Resistance Capacitance Method Flue Gas Moisture Content TesterZR-D13E

Short Description:

ZR-D13E flue gas moisture analyser is specially designed for on-line measurement of moisture in flue gas. This device based on Resistance capacitance method, could be used alone and could meet various operation conditions requirement, it also could be used combined with other relative devices. The length of probe could be custom made.


  • Moisture content: (0~40)VOL%
  • Temperature of chimney: ≤180℃
  • Accuracy: ± 2% RH at 25 ℃, (0~90)%RH ± 3% RH at (90~100)%RH
  • Battery: 3 hours,fully charged in 2.5h
  • Preheating time: ≤10min
  • Power Supply: AC(220±22)V,(50±1)Hz
  • Total length: 1m
  • Weight: About 2.4kg
  • Product Detail

    Specification

    Structure diagram

    ZR-D13E Resistance capacitance method flue gas moisture content Tester adopts the RC method(Resistance capacitance method) to measure the moisture content of the flue, and the whole process is accompanied by heat, which overcomes the complicated working conditions of high temperature, high humidity, high dust and high corrosion of the flue.The direct reading instrument is widely used in industrial field measurement, coal-fired power plant emission detection, environmental monitoring department testing and other fields.

    D13E_01

     

    Standards

    GB/T 11605-2017    Humidity measurement method

    >  HJ 836-2017            Determination of low concentration particulate matter in exhaust gas from stationary pollution sources gravimetric method

    Features

    • Excellent human-computer interaction experience

    > Color touch screen and key double control operation, real-time feedback, double guarantee.

    > The integrated mold design of the main shell is convenient, fast and reliable.

    > With lithium battery, it is convenient to view and print data at any time.

    • It can meet the requirements of multi-functional sampling

    > The extraction measurement of independent patented technology can be used alone or together with other online measurement equipment or handheld devices.

    > 316 stainless steel pipe is used, with an effective length of 1m as standard, and the optional extension pipe is suitable for flue with different thickness.

    > It has the functions of storage, inquiry, Bluetooth printing, USB export, RS485 communication, and optional Bluetooth communication.

    yingwen

     

    ZR-D13E Flue gas moisture content Tester(RC method)Working Process

     

    • Built in high-precision sensor

    > The resistance capacitance measurement principle adopts imported sensors to ensure the accuracy and stability of measurement and fast response time.

     

    • Automatic protection design

    > Special protection for the measuring probe can adapt to the complex and harsh measuring environment of high temperature, high humidity, high dust, high corrosion, static electricity and so on, ensure the measurement accuracy and effectively extend the service life of the measuring probe.

    > The whole process heat tracing of the sampling tube can effectively prevent the sensor from condensation.

    > The internal heating function is optional to prevent freezing and blocking the pipeline in extremely cold weather

    D13E_02

    Communication Connection Between ZR-D13E and ZR-3260

    Deliver Goods

    deliver goods Italy
  • Previous:
  • Next:

  • Parameter

    Range

    Resolution

    Error

    Response time

    Moisture content

    (0~40)VOL%

    0.01VOL%

    ±2VOL%

    <10s

    Pressure

    (60~130)kPa

    0.01kPa

    ±0.5kPa

    Temperature of chimney

    ≤180℃

    Accuracy

    ± 2% RH at 25 ℃, (0~90)%RH

    ± 3% RH at (90~100)%RH

    Repeatability

    Under the same measurement conditions, the difference between the two measurement results shall not exceed 2% RH

    Reproducibility

    Under different measurement conditions, the difference between the two measurement results shall not exceed 6% RH

    Data storage

    10000 groups

    Battery

    3 hours,fully charged in 2.5h

    Working condition

    (-20~50)℃, (0~95)%RH

    Preheating time

    ≤10min

    Power Supply

    AC(220±22)V, (50±1)Hz

    Total length

    1m

    Weight

    About 2.4kg

    Power consumption

    ≤200W

    1. Front filtration   2. Heat tracing pipe   3. High temperature prompt Sticker   4. Water storage bottle

    5. USB   6. DC24V   7. communication interface   8. Exhaust port   9. Handle   10. charging indicator

    11. Switch   12. touch screen   13. Key   14. sensor